SPL Metering
Sound pressure level measurement with A/C/Z weighting, configurable integration times, and Leq logging for compliance documentation
Measurement Types
dBFS Peak
Peak level in dB Full Scale. Instantaneous maximum sample value. Use for monitoring digital headroom.
dBFS RMS
RMS level in dB Full Scale. Average power of the signal. Standard for monitoring digital signal levels.
SPL RMS
Calibrated sound pressure level in dB SPL. Requires microphone calibration with a 94 dB reference.
SPL Leq
Equivalent continuous level over a time period. The standard for noise compliance and regulatory documentation.
Frequency Weighting Curves
A-Weighting
Approximates human hearing sensitivity. Strongly attenuates low frequencies and slightly attenuates very high frequencies. The most commonly used weighting for noise regulations.
A-weighting. -26 dB at 63 Hz, -3 dB at 500 Hz, 0 dB at 1 kHz, +1 dB at 2-4 kHz
C-Weighting
Nearly flat response with gentle LF and HF rolloff. Preferred for peak SPL measurements and low-frequency assessment. Better represents perceived loudness at high levels.
-3 dB at 31.5 Hz, flat 63 Hz–8 kHz, -3 dB at 8 kHz
Z-Weighting (Flat)
No frequency weighting applied. Flat response across the entire measurement bandwidth. Use for broadband energy assessment and system calibration.
Unity gain at all frequencies
Time Response
Peak
τ = Instantaneous | 20 Hz updateCatches transient peaks. Updates at 50 ms intervals.
Fast
τ = 125 ms | 10 Hz updateStandard for live monitoring. Responds to rapid level changes.
Slow
τ = 1.0 s | 2 Hz updateSmoothed reading for steady-state levels. Easier to read.
Smoothing Formula
SPL_smooth = (1 - α) × previous + α × new
α = 1 - exp(-dt / τ)
Leq Integration Periods
Equivalent continuous level over fixed time windows. Uses a circular buffer with running linear-power average.
All Leq modes update at 10 Hz. Linear power averaging: dB → power → average → dB
Calibration
SPL readings require calibration to convert digital levels to absolute dB SPL. Use a 94 dB calibrator placed over your measurement microphone.
Warning & Limit Levels
Configurable thresholds for visual alerts when SPL exceeds safe levels.
Warning Level
Default: 85 dB — OSHA action level
Limit Level
Default: 100 dB — exceeds safe exposure